Seven principles that hold everywhere on the site

These seven sentences hold on every page; a conclusion that breaks one of them is not published.

  • 01Claims and findings are written separately; repeating a claim is not verifying it.
  • 02A test not performed is not the same as a finding not present; both appear as separate rows in the scope.
  • 03Results are never given as percentages; the scale is verbal and comes from the vocabulary.
  • 04Every conclusion has a ceiling; if the evidence at hand does not raise it, no expert may raise it either.
  • 05A source grade states the kind of source, not the truth of the claim.
  • 06Decisions are per component; a conclusion about the beads does not extend to the imame.
  • 07The record is not a certificate; every version is verifiable and old versions are never deleted.

Decision flow

The verdict level is not picked by hand; it is the output of a versioned rule chain, in plain words:

  1. If the frames fail the quality gate, or the object falls outside the known hypotheses: not assessable.
  2. If the claim plainly contradicts the measurements: inconsistent with the claim. The measurement's own result is still written, not erased.
  3. If the scope is complete and the findings are consistent, the result can rise as far as the verdict ceiling of the policy in force. Under this policy version the ceiling is: Consistent findings.
  4. If the scope is incomplete the result drops to the scope ceiling — a missing instrument is not covered by optimism.
  5. If the next test would add much: further examination required. That is not a failure but a direction.
  6. Otherwise: inconclusive. That too is a valid outcome and is published as such.

Examination layers

An examination is layered by what it can see. The layer names are for explanation; what the record holds is the capture protocol and the verdict ceiling. No layer yields a percentage.

Examination layers
LayerWhat is examinedCapture protocolVerdict ceiling
K0Published or screen imageA photograph taken by someone else: an auction lot, a listing image, a screenshot. Lighting, scale and colour are outside our control.Outside the protocolInconclusive
K1Remote pre-assessmentThe owner shoots the prescribed frames on their own phone; scale is declared, not calibrated.Remote captureCapture over chatConsistent findings
K2Remote capture with a calibration card plannedThe same frames with a printed scale card in shot: size and colour become readable.Remote captureConsistent findings
K3Examination at the stationThe object is in our hands: weighing, calipers, microscope, UV, hydrostatic measurement; frames are shot under controlled light.Station captureConsistent findings
K4Station plus external laboratorySpectroscopic confirmation on top of the station examination; species and variety level opens only here, and requires separate consent.Station captureConsistent findings

Seven conclusion levels

The scale has seven steps and its order comes from the vocabulary; colour is only a slot, never the source of order.

Seven conclusion levels
StepLevelWhat it means
7VerifiedScope complete, findings consistent, and one explanation clearly ahead of the rest.
6High-confidence consistentScope complete; the leading explanation is strong but below the top threshold.
5Consistent findingsThe findings support an explanation; scope or evidence does not carry it higher.
4InconclusiveThe findings fit more than one explanation; nothing decides between them.
3Further examination requiredUncertainty remains, but a named test would largely close it.
2Inconsistent with claimThe measurements do not support the claim that came with the object.
1Not assessableThe frames or the object fall outside the limits within which the method works.

Conclusion level and evidence strength are different things

The verdict level says what we conclude; evidential strength says on what basis. They are separate scales and neither substitutes for the other: strong evidence still does not open the top level when the scope is incomplete.

Conclusion level and evidence strength are different things
Evidential strengthWhat it means
Extremely strongThe observations fit the proposed explanation almost to the exclusion of others.
Very strongThe observations are far more expected under the proposed explanation than its rivals.
StrongThe observations are markedly more expected under the proposed explanation.
Moderately strongThe difference is notable but not enough to carry a conclusion alone.
ModerateThere is a difference, but it must be read together with other findings.
LimitedThe observation is barely discriminating; it points, it does not carry.
AgainstThe observation favours the alternative, not the proposed explanation.

The scale is verbal; no numeric ratio or percentage is printed.

Maker attribution and its ceiling

Attribution to a maker is not a free opinion. For each maker we count how many first-hand and published reference works the archive holds; the qualifier stops where that count allows.

Reaching the reference target opens the “attributed to” step; half the target opens the “workshop of” step; below that, at most “style of” may be said. This ceiling binds the expert too; exceeding it requires a separate recorded decision and an audit trail.

Maker attribution and its ceiling
QualifierRankWhat it means
By8We conclude the work came from the maker's own hand.
Attributed to7The evidence points to the maker without settling that it is his own hand.
Workshop of6The work fits production from the maker's workshop; the hand cannot be separated.
Circle of5The work fits a hand working in the maker's circle.
Style of4Form and workmanship fit the maker's style; it cannot be tied to the person.
Influence of3The maker's influence is legible; no link to his production is established.
Unrelated2The available evidence does not establish any link to the maker.
Not by1The findings indicate the work is not the maker's.
Disputedoutside the rankingSources contradict each other; it sits outside the ranking and is shown as such.

Tests: what they say, what they do not

The rows come from the vocabulary's list of test types; when a test is added the table grows on its own. Hot-needle, scratch and burn tests are not performed in the default scope.

Tests: what they say, what they do not
TestWhat it saysWhat it does not sayInvasivenessConsent
Optical RGB imagingDocuments colour, surface texture and defects under controlled light.Does not say what the material is; an image alone does not discriminate.Non-contactNot required
Raking lightReveals surface topography: lathe marks, mould seams, wear.Does not date the marks; artificial ageing leaves marks too.Non-contactNot required
Transmitted lightShows internal structure: flow lines, bubbles, cracks, fills.Does not tie the structure to a material name; similar traces occur in different resins.Non-contactNot required
UV 365 nmFluorescence colour and intensity; surface treatment, repairs and fills.Gives no material identity on its own; similar fluorescence occurs across materials.Non-contactNot required
MicroscopeMagnified surface and internal inspection: drill mouth, mould traces, crystal and bubble forms.Gives no age and names no maker; similar workmanship recurs in different hands.Non-contactNot required
WeightRecords mass with its uncertainty; the input to the density calculation.Weight alone names no material; without volume it is just a number.Non-contactNot required
Caliper measurementBead and component dimensions, repeated on at least five representative beads.Size alone indicates neither period nor school.Non-contactNot required
Hydrostatic specific gravityDensity by underwater weighing; the strongest in-house measurement separating material families.Does not separate materials sharing a density band; yields no species level.Non-contactNot required
Simichrome testTransfer colour on a cotton swab; only a weak indication favouring the synthetic resin family.Does not confirm amber and carries no conclusion alone; it needs contact and consent.Limited contactConsent required
Hot point testNot performed by defaultNot performed in the default scope. It opens only with explicit consent and a written rationale.It leaves a permanent mark; smell-based discrimination is not reliable.Limited contactConsent required
Magnet testWhether the metal fittings show a ferromagnetic response.Gives no karat or alloy; the absence of a response does not mean precious metal.Limited contactConsent required
Static electricity testNot discriminatingRecords whether a rubbed bead holds a charge; for the record only.Does not separate amber from resin: post-war phenolic resins behave the same way.Non-contactNot required
Acid touchstone testDetermines metal karat with acid.It is destructive; never applied to beads or organic material.DestructiveConsent required
Bead removalPreparation stepNot a test but a preparation: a single bead is taken off the string for density measurement.It produces no finding of its own; without scope consent the measurement never opens.Limited contactConsent required
XRF elemental analysisElemental composition and karat in metal components.Does not identify organic material and cannot see the body under a plating.Non-contactNot required
FTIR spectroscopyExternal laboratoryThe spectral evidence that opens resin and amber discrimination at species level.It is not at the station, requires separate shipping consent, and by its mere presence raises no level.Non-contactConsent required
External laboratory reportExternal laboratoryRecords a third-party laboratory document and cites it.Does not vouch for the document's accuracy and does not replace our own measurement.Non-contactNot required
Brine float (1.13 g/cm³)Not discriminatingIn a 1.13 g/cm³ brine a bead that floats is a screening indication for amber, copal or a low-density resin/thermoplastic (PE/PP/PS), and a bead that sinks for phenolic resin, glass or a mineral.The bath is NOT saturated: saturated brine is ≈1.20 g/cm³ and acrylic and epoxy float in it too. Floating does not mean amber — copal, polyethylene, polypropylene and polystyrene float as well. Does not separate phenolic resin from polyester, celluloid or galalith; on its own it yields no material conclusion; it does not replace a hydrostatic density measurement.Non-contactNot required
Rub smellA resinous smell from a surface warmed by rubbing is a weak indication for fossil resin, and a phenolic (carbolic) smell for phenolic resin.A scentless result excludes no material; polish and coating can suppress the smell; it is a subjective observation, only its class value is recorded, and on its own it produces no conclusion.Non-contactNot required
Refractive index (refractometer)Measures how strongly the bead bends light, which pulls material families apart; acrylic and phenolic resin separate clearly on this reading.It does not name the material: the amber, agate and ivory ranges overlap. On a curved bead only the spot method can be read, and birefringence stays invisible.Non-contactNot required
PolariscopeClassifies the bead's optical character: amorphous (glass, resin, plastic), single crystal, or an aggregate such as agate and jade.It does not name the material, only the optical character of its family. An opaque bead gives no reading, and strain in cast resin cannot be told apart from strain in glass. Amber and cast resin routinely show anomalous double refraction (a strain pattern) between crossed polarisers; that observation is recorded as strain, not as doubly refractive.Non-contactNot required
Raman spectroscopyExternal laboratoryA molecular fingerprint taken at an external laboratory; used on dark and opaque beads and on resins that FTIR cannot separate.There is no conclusion rule for it yet: the record and the peak list are kept, but the system draws no inference from this test. Shipping also needs your separate consent.Non-contactConsent required
Morphometry (form measurement)Not discriminatingShape ratios (bead, head bead, hole) taken from a scale-card frame or with calipers; the input of the maker-fingerprint axis, recorded only with keys from the closed vocabulary.On its own it attributes neither maker nor workshop; comparison against a distribution is a separate decision.Non-contactNot required

Laboratory and station

Writing what we use binds us as much as writing what we do not. At the station:

  • Controlled lighting cabinet and a colour reference chart
  • Digital microscope with a 0.01 mm calibration slide
  • 365 nm long-wave UV source
  • Precision balance with class F1 reference weights
  • Hydrostatic weighing rig with water temperature measurement
  • Digital calipers and a gauge block
  • Transmitted and raking light rigs
  • Labelling and sample storage set for custody

There is no FTIR at the station; it is an external laboratory service and no examination stalls without it. Its absence limits not the conclusion but the level the conclusion may reach: without spectral evidence the material stays at family level and does not descend to species. Shipping a sample requires separate consent.

Who examines, who audits

The record carries no personal names; it carries the role, and which role decided.

Examiner
The role that measures and records findings. It enters findings; it cannot publish a conclusion alone.
Auditor
The role that independently reads scope, ceiling and rationale, and revisits conclusions by sampling.
External laboratory
The third party performing spectroscopic confirmation. Its document enters the record; the document's accuracy is theirs.

Every conclusion card carries a “decided by” field, filled at role level. A conclusion produced by automated evaluation shows as such; cases requiring human sign-off are marked separately.

What we cannot say

What follows are the record's own clauses, not marketing language, and they carry a version number.

Limitations text version 1.0

This document is an examination record: an expert opinion by DLINE LLC, based on an examination made on the date and with the methods, instruments and available references stated in it. It is not a certificate, a guarantee of authenticity, proof of ownership or origin, a legal trade permit, an insurance document or a binding valuation. Tests performed and not performed, and the levels of uncertainty, are shown in the "Scope" section. Rely only on the current version of the document, as verified at tesbihkar.com/k with the object number (TES) and the verification code printed on the card.

Read the full text

Scope levels

Three scopes are three depths of the same method. Each card reads its tests from the vocabulary; what a scope can and cannot say is stated separately.

  • Basic

    Guided station capture, measurement and instrumented observation. The strand stays intact and no material is taken.

    What it says

    States the material family, the structure, the cut, assembly integrity and condition.

    What it cannot say

    Gives no species or variety name. Strung hydrostatic measurement is screening only: the cord absorbs water and air stays in the bead hole, so no numeric specific gravity is produced.

    Hydrostatic measurement
    Strung — screening only
    Material conclusion level
    Family level
    External laboratory
    No
    Material conclusion ceiling
    Consistent findings
  • Full

    Everything in Basic, plus single-bead hydrostatic measurement, a consented surface test and consistency checks against the declaration.

    What it says

    Backs the family-level conclusion with a numeric specific gravity and names any conflict between declaration and measurement.

    What it cannot say

    Without sources, master attribution rises no higher than “in the style of”. No species name is written without spectral evidence.

    Hydrostatic measurement
    Single bead — numeric measurement, requires consent
    Material conclusion level
    Family level
    External laboratory
    No
    Material conclusion ceiling
    Consistent findings
  • Laboratory

    Everything in Full, plus spectral analysis at an external laboratory (FTIR / Raman) and the laboratory report entered into the record.

    What it says

    If the spectral evidence genuinely contributes to the reported hypothesis, the material conclusion descends to species or variety level.

    What it cannot say

    The mere existence of a laboratory sheet buys no level. No scope grants trade, export or ownership clearance.

    Hydrostatic measurement
    Single bead — numeric measurement, requires consent
    Material conclusion level
    Species / variety level
    External laboratory
    Yes — fee included in the price
    Material conclusion ceiling
    Consistent findings

Tests requiring consent are asked one by one. Without consent the test is not performed and the report says “not performed”; the conclusion level is limited accordingly.

Record service
Method · Tesbihkâr